Refined Storage vs Applied Energistics 2 for displaying a. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. 0:00 / 9:22. Since Minecraft 1. • 22 days ago. 3. This is obvious but its still the best tip for ae2 but cable anchors can prevent cables that would otherwise connect from connecting. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. All the autocrafting bits and bobs are still there and operational. I've attached leadstone pipe directly to the unit, but it didn't make a connection. ME Controller • ME Covered Cable - Fluix •. I'll tell you what are the differences between them, How to build a Hilber. Subnetworks Item Pipe Subnet Fluid Pipe Subnet Filtered Annihilation Plane Formation Plane Subnet Subnet using the Interface-Storage Bus interaction to act as a local sub-storage that the main network can access Another item pipe subnet, to return the charged items to the Pattern Provider AE is very specifically a one-way conversion. With that many ME drives, you'll need a lot of power (at default conversion, 224 RF/t just for the drives if you used 1k storage cells in all of them, or 704 RF/t if you used 64k storage cells; the power draws caused by the crafting terminal, storage bus, and cables are trickier to calculate). But depending on the choosen balance between less or more effort the actual amount max might vary between values like 32, 128, 512 or 1024. Large AE2 Network Design Guide - Applied Energistics 2 Tutorial #17 Just get back if/when you have more questions ;)P2P connectors don't transfer power. Layers alternate ME interfaces connected to the dense cable, so each ME interface has access to 3 (top/bottom) or 4 assemblers. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. them outside the network. the energy acceptor is now passing power to the main network, which is passing it to. The max channels the wireless connector can pass is 32, I believe you may be able to P2P more channels through it, but I haven't tried in a year. it's probably because of nested recipes, calculations will take forever to calculate tier 1 essence -> tier 2 -> tier 3 -> tier 4 -> tier 5 -> tier 6 essences needed to craft each tier of seeds. you are also advised to use storage drawers with ae2. 並列処理機構を組むにあたって重要な部分になります。. Side note: this is being done in the mining dimension since server restrictions keep me from doing all this in my main stoneblock base. 1. The ME P2P Tunnel is a block added by the Applied Energistics mod. The p2p network by itself is a normal ME network (with the one difference that it connects p2p tunnels instead of storage/crafting devices etc. AE2 - Device Missing Channel - Have to break ME controller and replace to fix. ME Controllers are thus disabled as a result, so anything relating to the. quartz cable wont connect networks, just power. 6. Edited to include versions (Minecraft 1. The mod is free and you can download it here. Read below for info and updates on the s. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is 7x7x7, and that you can only have 3 blocks in a row without an air gap. AE2 rv3 beta6. using an AE2 inscriber to make stamped plates). Pick a (big) number, try it. More info below!You can support me and the channel! Read more here: my first base I set up a 5x5 big reactor which was my power source for rf machines and ae2. Read below for info and updates on the s. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. That's 32x32 channels (1,024) going through a single dense cable line. The tutorial showcases how to craft and use the. Crafting CPU. P2P tunnels are always set to 1-to-n. This video covers the basic workings of Applied Energistics 2 related to Cables, Channels and Controller. When teh number stops changing, or you get bored, start the craft :P. To do this, however, you need something called channels. In games like Factorio, getting resources is automated right away. " Such networks are limited to only 8 Channels. In that setup each interface was adjacent to at least 3 assemblers, which was the max a Crafting CPU with no co-processors could utilize. 19. AE2 itself adds Certus Quartz Crystal, and makes use of vanilla's Nether Quartz as well. Even though it's highly unlikely that anyone would ever use that many machines, I still wanted to see how big I could theoretically make a Network given the logical constraints on the ME Controller. To use - place 2 Wireless Connectors and right click both with a Wireless Configuration Kit. The machine requires either a Wooden Crank (placed on top of the block) or power in the form of Redstone Flux (RF), Energy Units (EU), and Teslas (Energy can only be inserted from. I also learned about the drawer slaves. The ME Terminal is an item added by the Applied Energistics 2 mod. 1. The 1283 Spatial Storage is a device added by Applied Energistics that is used to store a 128 cubic block space. Every machine in AE2 takes up 1 channel. Trying To Understand Applied Energistics 2. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. So I'm playing ATM3, ive got an ME system going, 2 drives full, 1 controller, 6-7 terminals, 3 energy cells (currently 2 creative in addition). Various EnderIO, Thermal and Industrial foregoing machines for automation. The first step to getting started in AE2 is to acquire Quartz. Considering the vanilla item system, AE2 is even great at handling non-stacking items as long as their data is consistent (in particular, freshly crafted items). Different devices can be connected to the ME Network, such as an ME Drive, for the storage of items, or an ME Terminal, allowing for access to that storage. Basically the ME Controller and the ME Drives need to be in the same chunk, even if the ME Controller is split between 2 chunks and the cable you are using stays in 1 chunk it will still lag like crazy. anabsolutesloth • 4 yr. Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. The only cable that can handle 32 channels is ME Dense Cable that can be branched off of by ME Glass Cable. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. • 4 yr. At the center of the tower is dense cable. All controllers on a network must be connected pretty self explanatory. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. After implementing AE, I have a 5 block storage network, the contents of which can be. If you are using more than maybe 5 controller blocks combined you are doing it wrong (unless it's for aesthetics). If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. Each face of the Controller has 32 Channels, and items using channels trace the shortest path they can back to the Controller. A pair of items which are used to establish a connection between network bridges. To follow up on this, a popular alternative is called Refined Storage, and it can be simpler for new players. As a sidenote here : Dont do massive Storage drawer arrays if you have an AE2 system use AE2 Storage cells, drawers in huge amount will lagg you to death at one point. Top: Double-compressed item Lower-left: Compressed item Lower-right: Base item Extracting is performed with the left mouse button. Manages a single auto crafting task from start to finsh, built of various crafting units. The ME Wireless Access Point is a block added by the Applied Energistics 2 mod. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. This is a great feature. Synopsis []. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. ME P2P Tunnels allow for very dense cable connections using Applied Energistics 2 channels. All reactions. Applied Energistics 2: ID Name : appliedenergistics2:item. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. Controllers can have maximum of 2 adjacent blocks in at most 1 axis (the cannot have a plus sign rule). The 1k Storage Cell provides storage for 1024 bytes worth of items, and up to 63 different item types. I just use a normal reactor with a huge capacitor bank to store power. The ME Dense Cable is the only cable that can support 32 channel simultaneously so it can be used as a main data line to connect to another ME Controller or branch off into 8 channel. Interior: 135 Tunnels giving 4320 channels, 5 sides on the outside are required to extract these tunnels. You can tell this by watching the AE controller energy go above its max amount before resetting back to its max amount and repeating. Only one can be used as input, with any number of outputs. If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. Many mods also offer a similar feature, but all i know of are worse and meant for earlier in progression than AE2. #2. 94. 15+ we switched to using semver. It is the new and overhauled version of the original Applied Energistics mod. An ME interface allows you to pump things into it. Gaming. The island bridges were ~80% full. I just logged on and now its doing nothing at all :S really strange, i can access the system/items but its not processing anything and there are still ores and dusts in the system, also there. For example, RF to/from EU. at least one Storage Block (ME Drive or ME Chest) The following are rather optional. 8 channels is always maximum, after that you need a controller. r/feedthebeast. setInterfaceConfiguration ( [slot:number] [, database:address, entry:number [, size:number]]):boolean. Aug 20, 2015. you want interfaces to be completely covert with assemblers for maximum efficency and speed interfaces/assemblers can only transfer up to 8 channels, so that would be your max. . Even mekanism has a system for it, though in this case its worse than. 5. 0 alpha that provides wireless connections. This can be useful to move a multi-block stucture or a processing machine set-up. Store high quantity. This type of network is known as an "ad-hoc" network. The ME Controller is a block added by Applied Energistics 2. My Very First Quartz. 4mj/t for a ME drive filled with 4k vs 4. If you make the line the p2p ports are on connect to a controller, you can also connect the p2p face of the p2p port onto the same controller, allowing you to use the controller to connect. manually mine. Ah ok, so just a bigger set up I guess. You can attach the storage bus to the bottom of the drawer controller. 2. 1. Maximum size of the ME Controller multiblock is now configurable. One click will extract a single item. ---> I only have 3 blocks in a row. There is a way to circumvent this. The 1k ME Storage Cell is the first tier of item storage added by Applied Energistics 2. you can also use the Cell Workbench to blacklist or whitelist cells to accept or block certain items then use the IO Port to transfer items from the cell to the system. Last modified on 03/09/2014 10:04 PM CDT. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. or add the modCompileOnly line to your existing dependencies task to your build. Im happy to present you MyModpackList a site inspired by MyAnimeList and allows you to make your own list of modpacks you want to play/already played and rate them ! We need beta testing so any feedback is apreciated (1 / 2. If you want to see if you can access your ssn from your ae2 you'll need everything above plus some ME cables and a storage bus. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. Applied Energistics 2. I'm finding that when my ME network gets to a larger size (to the level of hundreds of connected interfaces/buses), it keeps freezing up. but thats buggy isnt it ? Theoretically the max size of a ME system depends on the number of faces of your controller you can access and extract channels from. How to make the inscriber, processors, fluix crystals, and complete setup. 1) Wire the 5 p2p ends from one side, the bottom 2, and the bottom 1 on the back side. I'm not gonna count but it looks like OP is using all 192 channels from a single controller block. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. 3 Dedicated and prioritized external storage with overflow: 2 Inputs and Outputs. 1. You can deduct the inputs though, if they start from another side of the ME controller. The ME Controller allows you to start a ME network within minecraft. I opted to use Minetweaker to remove that barrier to entry. More than enough channels. 1. The storage cell can be formatted before use to only accept certain items in the Cell Workbench. With the channel mechanics that are currently in place, you can place a controller surrounded by 6 different color dense cables and then place 32 p2p connections on each cable, for a theoretical max of 6144 channels per controller, so why in the world would you ever need to have more than one. The item type cap is 61 *per drive*, so once you get 3-4 drives you're pretty much set. I have the same 5x5x5 controller working just fine on FTB Revelations as well so it isn’t a limitation that you’re running into. That, and the total size of the. I've added a new block to AE2 Stuff 0. In AE2 the ME Interface is basically instantaneous, so it should be limited by whatever is pushing the items into it. ME Cable is added by Applied Energistics. An updated guide on large ME controllers and P2P networking. 128³ Spatial Storage. That means it can transfer 16krf/t. So will take the max amount the conduit can give (up to 80/400) and drain your reserves. 14 others) automatic. 大容量チェストMODとして. シングルプレイ. . MEチェスト1. Moving the controller to the same chunk as the Super Soaryn Drive and the ME Drives made the server tickrate go from 8 to 20 in about 2 minutes. Basically, what this means is that of the 3 axis of the block (Up/Down, East/West, North/South) only one of them may have. It is used to interact with a group of drawers. 2852;. Keep in mind that controllers are only really useful if you can get at them to make connections. You can use 32 interfaces. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). Applied Energistics 2. i would suggest using a RFTools crafter to do a passive autocraft to keep stock of each level of essence (using drawers or something) as opposed to. Applied Energistics 2 (AE2) is a comprehensive mod for Minecraft that introduces a unique approach to in-game inventory management. while on the ME Drive or Chest GUI click the top right icon then increase the priority. 14. All the stuff along the outside could be improved and you could easily add a couple of hundred by not having everything feed back into the controller as I did. First Appearance : MC 1. I used two lengths of fluix smart cable - I'll call it cable 1 and cable 2. e. That seemed to be the problem, I got my me system working again, I just had to remove and change some cables, thx. ME Controllers output 32 channels per block face, so one singular controller has 6 faces x 32 channels = 192 total channels. Or just do the level emitter thing, or external automated crafters and pre. 1. r/feedthebeast. Theinventor10. Examples of these are enderio, project red, etc. . When I started my Applied Energistics 2 setup I used 2x2x4 pillars consisting of 8 ME Interfaces and 8 Molecular Assemblers. . I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. r/feedthebeast. Read below for info and updates on the subject!Fantasy This page is about the ME Controller added by Applied Energistics 2. . If that doesn't work they aren't compatible and you should instead build some import busses to start. They only produce 10 AE/t (5 EU/t or 20 RF. You might as well just make a converter for whatever systems. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. ago. I went into a bit more detail a few minutes before you posted your question. It's the best balance between capacity and storage space. 23. Normally in the inside of a corner you can't get 32 channels out of each face as if you place a cable there it'll connect to both faces and only let 32 channels through itself, wasting anywhere from 32 channels in a regular corner, and 128 in. 20. The ME Controller has a maximum length of 7 blocks total B. Once it's in. Connections are point-to-point - you can't connect more than 2 blocks together. Key things to remember about channels: Each side of a controller block can support 32 channels. This is mainly done to improve performance because ae2 would have to do a lot of network logic calculation for those connections the way it is coded. The current AE2 developer has said that he does not want the storage system to be a power provider. You can connect your power source directly to the controller if you'd like, or to a Power Relay. The dense cable is connected to the controller via p2p interface. If it's not ok, halve it, try again. Wiring has its own simple concepts that go along with this channel system: 0. The main island was full, I basically added another p2p to the controller when it ran out. tterrag1098 • EnderIO/Chisel Dev • 9 yr. One dense cable gives 32 channels, which is enough to autocraft 288 items (9 items per interface; molecular assemblers don't require a. Type : Item Stackable : Yes (64) Solid : Yes Transparent : No Affected by Gravity : No Emits Light : No Flammable : No Required Tool : The Cable Anchor is an item added by the Applied Energistics 2 mod. Channels are just a funny way to say bandwidth. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. Server address is sb. My understanding of the rules of Controllers that there can only be one set of controllers per network, the controller multiblock can be 7*7*7 at the largest, and all blocks must have at least 2 adjacent sides sides exposed. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. . 6 6.バニラのチェストとアイテムの受け渡し. 이 블럭의 역할을 알기 위해선 우선 '채널'에 대해 알아야 한다. you can feed power into your network via an energy acceptor or using quartz cable (not fluix). The Drawer Controller is a block added by Storage Drawers. :D. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. D:perTickNetworkBridge= the number of AE units required to power a Quantnum Network Bridge. Large RS systems are hell on the server and will cause lag spikes that can affect everyone for multiple seconds at a time if you are on multiplayer. extenders= the maximum number of wireless boosters ( capped at 64 ). When your networks starts to grow, so must your ME Controller. I didn’t use it much, but rushing rf tools storage scanner acts like a ae2 system that uses inventories in the world. If a controller remains red, one of the rules are broken and the controller is. I have chunk loaders at my Jurassic park and my main base. An ME System is a system in Applied Energistics 2 that uses a ME Controller and a combination of other items found in Applied Energistics 2. It allows items to be inserted into or extracted from the ME System it is connected to. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Don`t. Code; Issues 147;. Hallo,in diesen Video erfahrt ihr wie ihr ein eigenes Me-System bauen könnt. . 2 One route to the controller: 1. Use a quartz cable to connect the smart cable to the ME controller hub, the huge one and remove the intermediate controller. In IC2, the basic solid-fuel burning Generator produces 10 EU/t, and the most end-game generator (Liquid Cooled Reactor) can produce about 1,000 EU/t. Commonly used for Sub-Networks. 2. 5 Some examples of sub-networks and their use . Part of a multi-block structure, used to digitally store the blocks within a certain space determined with the use of the Spatial Pylon. My usual go-to design using an 8 Controller Block doughnut (1024 Channels) is already extreme overkill. you want interfaces to be completely covert with assemblers for maximum efficency and speed interfaces/assemblers can only transfer up to 8 channels, so that would be your max. It is used to charge charged items and charge Certus Quartz Crystals into Charged Certus Quartz Crystals. Welcome to the Applied Energistics Mod!This mod is all about digital storage and is much more complicated to it's counter part Refined Storage. The ME Controller is a block added by Applied Energistics 2. The ME crafting terminal from ae2 tutorial. The test now included a controller, import bus, a storage block (I tested a few, same results, one being modded, the black hole unit from IF), cryotheum flux ducts and capacitor banks. 2 Vanilla+ modpack for people who would just like to take it slow and enjoy a nice, cohesive and consistent experience! 380. for me craft i for 5x5x5 with 50% cpu, my crafting normaly gets stuck waiting on one machien (i. Current versions of OpenComputers add the . e. I then use an Ender IO power monitor to turn the reactor on and off. 2. An ME Controller has a built in power buffer, while an Energy Acceptor has practically none. ME Controller. 1 チュートリアル. Just put one ME Storage Bus on the Drawer Controller. ) All Spatial Pylons must be in the outside bounding box. com wrote: the existing config works, but i want that it only works with a me controller and the controller i cant find. So what is the most channels you could get? The size of the ME Controller must be within 7x7x7; else it will turn red. 139. アイテムをデジタルデータ化して貯蔵、運用するといった趣のMOD。. ) Things like ME Controllers, Inscribers or Crystal Growth Accelerators, do not use channels. will post updates on free time to show my advancement in the base. I don't really get this current trend. After making the room proper, I discovered that the drawer controller can control drawers that are 12 blocks away from the controller in any direction. Having the 4 cables on the tops of them causes conflicts. With the way tags and flattening works, it also would not be of much use. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. ItemMultiPart:120. )液体の管理に使用する装置も専用のものが追加されています。MEコントローラやMEドライブまたはMEチェストはAE2のものと同じものを使いますが、液体の管理をするときはドライブかチェストにME液体ストレージセル(ME Luqid Strage Cell)を入れて使用します。液体. #minecraft #moddedminecraft #appliedenergistics2 toastonrye's AE2 Setpoint Controller, a work in progress!A weekend project I'm probably never going to finis. However, a regular glass cable will only hold 8. But for whatever reasons some are already. If you need more than 8 channels, you need a ME Controller. 0:00 / 9:22. Up to 64 Boosters may be installed in. I:max. So in my picture you can kinda see a fluix cable running along the bottom of the controllers - this is attached to the controllers with quartz fiber (which allow AE2 power. The only way to kick-start it seems to be breaking parts of the ME controller up and placing them back down. More posts you may likeDrawer A. The last bit is power. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. The ME Controller's texture will change to display the stored energy level for network use. ago. LP was available very early on and with almost default recipe, was able to do pretty much everything AE2 can (just with a significant speed and size disadvantage), and even had integration with AE2 to make transitioning between them easier (literally a pipe to an ME Interface and the LP system could access the storage of the ME System, so you. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. Build a Storage Drawers system, connect the Drawer Controller to the ME system with a Storage Bus (this will allow the AE system to see everything in the Drawer System that is inside a 12x12 area). It is the new and overhauled version of the original Applied Energistics mod. • 18 days ago. #4. and click on the faces until the one facing the ME Controller turns orange. 3k. Has 8 channels to play with. like it doesnt exist. #2. Channels. A "Sub-Network" is a separate ME Network that augments another network. As long as all rules are followed and powered, the controller should glow and cycle colors. The conversion is 4 RF -> 2 AE <- 1 EU. In the network tool GUI of AE2 (access by right clicking an AE2 device on a ME network such as a cable), there is a title "network details", followed by "stored power" (0 RF [0 AE] , as there is no energy cell and I'm powering via tesseract), max power (16 kRF [8 kAE]), then a list of AE2 devices on the network. The tutorial showcases how to craft and use the. I like it as it's a challenge. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. This shape, a fractal called a Hilbert Curve, has the largest known number of. The bus priority should be extremely high, set it to 10000 to be positive. Added GTEU p2p. One Route to the controller: AE2 devices auto-connect. Release. Nope. This can be done by using the "ME IO Port". Im happy to present you MyModpackList a site inspired by MyAnimeList and allows you to make your own list of modpacks you want to. does ANYONE know why there is no ME controller in the…. Not too shabby. Use quartz to supply power and short-circuit the ME signal (force it to go through the p2p); just go around the p2p with quartz. At its most basic, the ME Controller is just a single block, however, it can be expanded to the size of a 7x7x7 multiblock if you so wish (with some restrictions). Today we will. I suggest using a Bulk Storage solution, and then for general storage. Each side of ME controller provide 32 channels. And so forth. However, you will need to reconnect a P2P bus (per dense cable). In-Game Version. items in storage drawers and connect the controller to the ME network with a storage bus. The mod's Energy Acceptor and Controllers accepts both Forge Energy (FE, RF, µI, CF, IF, etc. Applied Energistics 2; Main File 1. Thats: 16 * 1024 * 1024 * 10 * 32 = 5'368'709'120 items per side of an ME controller. Then a single stand of smart cable to wherever I'm working at. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the.